當前位置:
依客思防爆科技有限公司 >
產品中心 >
防爆軸流風機風扇類 > 依客思CBF-200/250/300/350/400/450/500/550/600/650/700碳鋼防爆軸流風機0.37KW
依客思CBF-200/250/300/350/400/450/500/550/600/650/700碳鋼防爆軸流風機0.37KW
| 產品型號: |
CBF-200/250/300/350/400/450/500/550/600/650/700 |
| 品 牌: |
依客思 |
|
|
| 所 在 地: |
湖北武漢 |
| 更新日期: |
2026-07-20 |
| | 加工定制:是 | | 品牌:依客思 | | 型號:CBF-200/250/300/350/400/450/50 | |
| | 電流:10A A | | 溫控范圍:22左右 | | 尺寸:400*300*200 cm | |
| | 風量:10500m3/h m3/h | | 適用范圍:適用于石油采煉、儲存、化工、醫 | | 重量:12KG-56KG ㎏ | |
| 名稱 |
型號規格 |
功率(kw) |
風量m3/h |
轉速(r/min) |
| 防爆軸流風機 |
CBF-200 |
0.18 |
|
1450 |
| 防爆軸流風機 |
CBF-250 |
0.18 |
|
1450 |
| 防爆軸流風機 |
CBF-300 |
0.18 |
2280 |
1450 |
| 防爆軸流風機 |
CBF-400 |
0.37 |
2880 |
1450 |
| 防爆軸流風機 |
CBF-500 |
0.55 |
5700 |
1450 |
| 防爆軸流風機 |
CBF-600 |
0.75 |
8700 |
1450 |
| 防爆軸流風機 |
CBF-700 |
1.1 |
10200 |
1450 |
| 防爆軸流風機 |
CBF-750 |
1.5 |
10500 |
1450 |
防爆軸流風機CBF-400 直徑400mm 功率0.37KW電壓380V適用范圍:
1、爆炸性氣體混合物危險場所:1區、2區。
2、爆炸性氣體混合物:ⅡA、ⅡB。
3、溫度組別:T1~T4。
4、防爆標志:ExdⅡBT4。
防爆軸流風機CBF-400 直徑400mm 功率0.37KW電壓380V特點:
1、防爆軸流風機CBF-400由防爆電機、葉片、風筒等部件組成。
2、風機采用鋼板卷曲而成,具有較高的強度。
3、電機能耗低、壽命長。
2、電纜布線。
帶百葉窗CBF-300防爆軸流風機葉片角度35度 0.12KW/0.18KW技術參數:
以下參數都為***,如需更改,也可按照客戶的需求定制!
1、風葉直徑:400MM;
2、電機功率:0.37KW;
3、轉速:1450轉/分鐘;
4、電壓:220V/380V。
防爆軸流風機CBF-400 直徑400mm 功率0.37KW電壓380V工作條件:
本系列產品工作條件為:交流50Hz、電壓220V/380V,無重腐蝕和***粉塵的場所,防爆性能符合GB3836.1-2000《爆炸性氣體環境用電氣設備 ***部分 通用要求》和GB3836.2-2000《爆炸性氣體環境用電氣設備 第2部分 隔爆型“d”》的規定,防爆標志:ExdⅡBT4,并取得防爆合格證。
防爆軸流風機CBF-400 直徑400mm 功率0.37KW電壓380V裝方式:
固定式:固定式又可分為壁式,也叫管道式,將風機固定在通風口。
崗位式:也稱為移動式,帶崗位支架,支架上帶有滾輪,可隨處移動,使用方便。
注意:請訂時,注明需要的安裝方式以便為您配備相應的安裝附件。
帶百葉窗CBF-300防爆軸流風機葉片角度35度 0.12KW/0.18KW用和特點
防爆風機是應用在有爆炸危險的場合的風機,它除了具備工況所要求的風機特性之外,還必須滿足防爆的要求。
一方面,防爆風機必須采用防爆電動機;另一方面,防爆風機的過流部件(葉輪、蝸殼等)必須采用軟硬配合的材質,通常來說,也就是旋轉部件和固定部件之間,必須一軟一硬,以防止發生故障時,部件之間摩擦或碰撞產生火花。比較常見的材質配合是,葉輪的葉片、前盤、后盤及葉片鉚釘為2A01材質的硬鋁,蝸殼采用鍍鋅板。
如果葉輪采用硬鋁材質不能滿足強度要求,也可以采用鍍鋅板材質葉輪,而在蝸殼表面覆蓋一層薄的硬鋁襯里。
帶百葉窗CBF-300防爆軸流風機葉片角度35度 0.12KW/0.18KW機的區別:
1、采用的電機不同,防爆風機必須使用防爆電機。
2、對葉輪材質及葉輪相對應的機殼內壁位置材料有要求,要求它們在萬一出現碰擦情況時不會產生火花,比如使用鋁風葉和鐵內壁,或者鐵風葉并在內壁加鋁環。
3、防爆風機對葉輪與機殼的間隙有下限要求。而風機為了追求效率往往對間隙有上限要求,互為矛盾。
4、防爆風機對進出口端的安全防護要求更嚴。
Explosion-proof axial fan CBF-400 Diameter 400mm Power 0.37KW voltage 380V Application range:
1, explosive gas mixture dangerous places: Zone 1, Zone 2.
2, explosive gas mixture: ⅡA, ⅡB.
3, temperature group: T1 ~ T4.
4, explosion-proof mark: ExdⅡBT4.
Explosion-proof axial fan CBF-400 diameter 400mm Power 0.37KW voltage 380V Features:
1, explosion-proof axial fan CBF-400 is composed of explosion-proof motor, blade, duct and other components.
2, the fan is made of steel plate crimped, with high strength.
3, low motor energy consumption, long life.
2, cable wiring.
With louver CBF-300 explosion-proof axial fan blade Angle 35 degrees 0.12KW/0.18KW Technical parameters:
The following parameters are ***, if you need to change, can also be customized according to customer needs!
1, blade diameter: 400MM;
2, motor power: 0.37KW;
3, speed: 1450 RPM;
4, voltage: 220V/380V.
Explosion-proof axial fan CBF-400 Diameter 400mm Power 0.37KW voltage 380V Working conditions:
The working conditions of this series of products are: AC 50Hz, voltage 220V/380V, no heavy corrosion and *** dust place, explosion-proof performance in line with GB3836.1-2000 "Electrical equipment for explosive gas environment *** part of general requirements" and GB3836.2-2000 "Electrical equipment for explosive gas environment Part 2 Flameproof type "d" provisions, explosion-proof mark :ExdⅡBT4, and obtain explosion-proof certificate.
Explosion-proof axial fan CBF-400 Diameter 400mm Power 0.37KW voltage 380V Installation method:
Fixed type: Fixed type can be divided into wall type, also called pipe type, the fan is fixed in the vent.
Post type: also known as mobile, with post bracket, bracket with rollers, can be moved anywhere, easy to use.
Note: Please specify the required installation method when ordering so that you can be equipped with the appropriate installation accessories.
With louver CBF-300 explosion-proof axial flow fan blade Angle 35 degrees 0.12KW/0.18KW usage and features
Explosion-proof fan is a fan used in situations with explosion risk, which in addition to having the characteristics of the fan required by the working condition, must also meet the requirements of explosion-proof.
On the one hand, explosion-proof fans must use explosion-proof motors; On the other hand, the flow parts of the explosion-proof fan (impeller, volute, etc.) must be made of soft and hard materials, generally speaking, that is, between the rotating parts and the fixed parts, there must be a soft and a hard to prevent the friction or collision between the parts when the fault occurs. The more common material matching is that the blade of the impeller, the front disc, the back disc and the blade rivet are 2A01 hard aluminum, and the volute is galvanized.
If the impeller can not meet the strength requirements using duralumin, it can also use galvanized plate impeller, and cover the volute surface with a thin duralumin lining.
With louver CBF-300 explosion-proof axial fan blade Angle 35 degrees 0.12KW/0.18KW machine difference:
1, the motor used is different, explosion-proof fan must use explosion-proof motor.
2. There are requirements for the material of the impeller and the inner wall of the casing corresponding to the impeller, requiring that they will not produce sparks in case of collision, such as the use of aluminum blades and iron inner walls, or iron blades and aluminum rings in the inner wall.
3. The explosion-proof fan has a lower limit requirement for the clearance between the impeller and the housing. In order to pursue efficiency, fans often have upper limit requirements for clearance, which are contradictory to each other.
- The explosion-proof fan has stricter safety protection requirements for the import and export end.